CV2123 CS Repair Tips




Search: CV2123 CS
Results 1
MakeModel Ch.SymptomProblem SolutionSolutionBy:
Sharp CV2123 CS
Field fault / general modificationAdd a 1N4148 diode from the emitter of Q509 to cathode of D513 cathode to emitter of Q509, Pt No. RH-DX0045BMZZ, change R534 to 390ohms Pt No. VRS-TV1JD391J and add a fuse in series with L607 and L608 Pt No. QFS-J1023CEZZ